Streszczenie treści zawartej na stronie nr. 1
Installation Instructions
®
Renaissance Electric Range
with induction cooktop
Models: RR30NS[-C], RR30NFS[-C], RR30NIS[-C] and RR30NIFS[-C]
Part No. 105910 Rev. C
Streszczenie treści zawartej na stronie nr. 2
Table of Contents Important Safety Instructions .....................................................1 Installation Instructions ...............................................................8 Important Information About Safety Instructions.........................1 Verify the Package Contents ......................................................8 Safety Symbols in this Manual ...................................................1 Installing the Anti-Tip Bracket .................................
Streszczenie treści zawartej na stronie nr. 3
Important Safety Instructions Important Information About Safety Symbols in this Manual Safety Instructions DANg ER The Important Safety Instructions and warnings in this manual Immediate hazards that w ILL result in severe personal injury or are not meant to cover all possible problems and conditions death. that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. wARNINg Always contact the Dacor Customer Service Team about probl
Streszczenie treści zawartej na stronie nr. 4
Important Safety Instructions General Safety Precautions To reduce the risk of fire, explosion, electric shock, serious injury or death when installing or using this appliance, follow basic safety precautions, including the following: wARNINg wARNINg • Read all instructions before using the appliance. • Install or locate this appliance only in accordance with these installation instructions. • Keep packaging materials away from children. Plastic sheets and bags can cause suffocation. •
Streszczenie treści zawartej na stronie nr. 5
Product Specifications Electrical Requirements wARNINg IMPORTANT: Observe all governing codes and ordinances (Models Ending with -C) during planning and installation. Contact your local building Range models RR30NS-C, RR30NFS-C, RR30NIS-C and department for further information. RR30NIFS-C come with a factory installed 4-wire appliance cord with NEMA 14-50P plug. Electrical Requirements (All models • For freestanding ranges installed in Canada, a factory installed 4-wire appliance cord w
Streszczenie treści zawartej na stronie nr. 6
Product Specifications Product Dimensions Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated A Front of open door B Front of handle C Front panel D Rear of front panel 1” (2.5 cm) Backguard thickness 9” (22.9 cm) backguard* 6” (15.2 cm) backguard* 3” (7.6 cm) backguard* RR30NI[F]S: RR30NS RR30NIS 3/8” (9.5 mm) Dimension RR30NFS RR30NIFS thick top trim 46 1/4” 46 1/16” External handle A (117.5 cm) (117.0 cm) RR30N[F]S: shown, some models 35” full stainless have integral handle (8
Streszczenie treści zawartej na stronie nr. 7
Installation Specifications • The electrical junction box/receptacle must be located so Cabinet Layout that it does not interfere with the range when it is installed and under operation. In addition, the junction box/receptacle must be located so the range can be removed for service and wARNINg remain connected to power. • Observe all governing codes and ordinances during Cabinet and Countertop Preparation planning and installation. Contact your local building department for further in
Streszczenie treści zawartej na stronie nr. 8
Installation Specifications Cabinet Cutouts for Self-Rimming Installation (Models RR30NIS and RR30NIFS Only) Countertop 1 5/8 (41.1 cm) • The self-rimming installation of the RR30NI[F]S range max. thickness creates a “built-in” look where the range trim overlaps and rests on the countertop on both sides and in back. (see diagrams) • IMPORTANT: When installing the range in this configuration, ventilation must be provided to allow for cooling of the ranges internal components. See diagram,
Streszczenie treści zawartej na stronie nr. 9
Installation Specifications Cabinet Cutouts for Self-Rimming Installation with Raised Vent (Models RR30NIS and RR30NIFS Only) • Trim kit PN ATKR30SR is required for proper installation of a raised vent with this range. Countertop 1 5/8 (41.1 cm) • The self-rimming installation of the RR30NI[F] S range and ERV30[15] raised vent create a max. thickness “built-in” look where the range trim overlaps and (see diagrams) rests on the countertop on both sides and the raised vent trim overlaps the
Streszczenie treści zawartej na stronie nr. 10
Installation Instructions 1. Determine the location of the range center line and front Verify the Package Contents panel when the range is in its final position based on the Product Dimensions on page 4, and the actual cabinet/ Verify that all the components below have been provided. If cutout dimensions used for the installation. any item is missing or damaged, please contact your dealer immediately. Do not install a damaged or incomplete appliance. 2. Determine the required position of t
Streszczenie treści zawartej na stronie nr. 11
Installation Instructions To determine if the base plate is high enough: a. Determine the location of the range center line and front panel when the range is in its final position based on the Product Dimensions on page 4 and the actual Drywall cabinet/cutout dimensions used for the installation. Anti-tip b. Determine and mark the required position of the anti-tip bracket Notch bracket, based on the diagram below. Push the bracket up against the wall in the mounting location. c. Using a pe
Streszczenie treści zawartej na stronie nr. 12
Installation Instructions Backguard Installation Electrical Connection If installing a backguard or changing the factory installed backguard, install it before moving the range into position. Do not wARNINg install a backguard if installing a raised vent. • Before proceeding, turn off power to the circuit to which the appliance will be connected at the circuit breaker panel or Raised Vent Installation fuse box. If installing a raised vent, install it before moving the range into • If the
Streszczenie treści zawartej na stronie nr. 13
Installation Instructions Connecting Conduit to the Range L1 terminal NOTE: See page 14 for instructions to connect an appliance cord to the range. Neutral terminal 1. Remove the range electrical access cover from the back of the range. Jumper link 2. If using a 4-wire connection, loosen the grounding screw and remove the neutral to ground jumper link. 3. Remove the nut from the conduit strain relief (not included). L2 terminal 4. Slide the wires and the end of the strain relief into the hole
Streszczenie treści zawartej na stronie nr. 14
Installation Instructions Electrical Connection (cont.) Connecting the Conduit to the House Electrical Junction Box wARNINg • Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit. • Do not ground the appliance to a gas supply pipe or hot water pipe. • A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials. Any insulating materials must be jumped with a Conne
Streszczenie treści zawartej na stronie nr. 15
Installation Instructions Separate No. 10 (minimum) copper grounding wire Fasten clamp tightly on pipe Connection to house power supply Connection to house power supply Junction box Junction box Wire nut Wire nut 4 places 3 places RED WHITE RED WHITE GREEN BLACK GREEN BLACK Conduit to Conduit to appliance appliance 3-w ire Conduit-Junction Box Connection 3-w ire Conduit-Junction Box Connection with External g round 13
Streszczenie treści zawartej na stronie nr. 16
Installation Instructions 5. Slide the end of the appliance cord into the strain relief from Electrical Connection (cont.) the bottom of the box. See facing page. 6. Connect the white (neutral) wire to the neutral terminal in the Appliance Cord Connections - w here Local box. Code Permits 7. Connect the L1 wire to the L1 power supply terminal inside the box. wARNINg 8. Connect the L2 wire to the L2 power supply terminal inside Do not connect the green appliance wire to the neutral (white)
Streszczenie treści zawartej na stronie nr. 17
Installation Instructions L2 L1 Neutral Neutral Ground L2 L1 3-w ire Appliance Cord Plug 4-w ire Appliance Cord Plug L1 terminal L1 terminal Neutral terminal Neutral terminal L2 terminal L2 terminal Jumper link Link removed Ground screw L1 wire L2 wire White wire L2 wire Green wire White wire L1 wire Strain relief Strain relief 3-w ire Appliance Cord Connection - 4-w ire Appliance Cord Connection - w here Local Codes Permit w here Local Codes Permit 15
Streszczenie treści zawartej na stronie nr. 18
Installation Instructions Installing the Range Re-installing the Oven Door Peel off the protective layer of plastic that covers the stainless steel surfaces. wARNINg To avoid personal injury or damage to the door from it Freestanding Installation falling off its hinges: 1. Measure from the floor to the countertop and adjust the • Make sure that the notch on the bottom of each hinge rests leveling legs as required to position the top frame at the on top of the lower lip of each hinge rece
Streszczenie treści zawartej na stronie nr. 19
Installation Instructions Verifying Proper Operation Installation Checklist 1. Remove any packaging from inside the oven. wARNINg 2. Slide the oven racks onto the supports inside the oven chamber according to the use and care manual. To ensure a safe and proper installation, the installer must perform the following checklist to ensure that no part of the 3. Prior to operating the range, please read the accompanying installation has been overlooked. Proper installation is the use and care
Streszczenie treści zawartej na stronie nr. 20
Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.com